Ideal for all pH testing, water purification applications,
wastewater regulation, aquaculture, hydroponics, colloidal silver, labs &
scientific testing, pools & spas, ecology testing, boilers & cooling
towers, water treatment, wine, coffee, agriculture and more.
FEATURES
- Measures
pH and Temperature
- Auto-ranging
three point calibration with digital fine tuning
- Includes storage
solution in a sponge embedded in a clear cap
- Waterproof
housing (IP-67 rating)
- Simultaneous
temperature display
- Measurement
Range: 0-14 pH
- Digital
automatic calibration (one point), with digital fine tuning
- Automatic
Temperature Compensation (ATC)
- Auto-off
function, data-hold function and low-battery indicator
- Display:
large and easy-to-read LCD screen includes simultaneous temperature
reading
- Replaceable
Sensor (model SP-P2)
- Factory
Calibrated: The PH-200 meter is three-point checked and factory
calibrated to pH 7.0. It can be re-calibrated to any point in its range
with digital calibration using the push buttons.
- Includes
a cap, batteries, lanyard, and pH 7.0 buffer
SPECIFICATIONS
pH Range: 0 - 14
Temperature Range: 0-80 C; 32-176 F
Resolution: 0.01 pH; Temperature resolution is 0.1 C/F
Accuracy: +/- 0.02 pH; Temperature accuracy is +/-2%
Calibration: Digital automatic calibration (one point) with digital
fine tuning
Minimum EC/TDS: 5 uS/10 ppm
Electrode: Replaceable glass sensor and reference tube electrodes
Housing: IP-67 Waterproof (submersible; floats)
Power source: 3 x 1.5V button cell batteries (LR44 or equivalent;
included)
Dimensions: 18.5 x 3.4 x 3.4 cm (7.3 x 1.3 x 1.3 inches)
Weight: 96.4 g (3.4 oz)
FAQs
The sponge in my cap is dry. Is this okay?
Yes. During shipping, it is possible for the solution to leak or dry. This will
not damage your meter, and it's perfectly fine, since the cap was on and it was
in the box. Prior to use, pour a small amount of the electrode storage
solution (from the Mylar packet) into the sponge so that it's moist.
Put the cap back on and allow the sensor to soak for 15 minutes standing
upright. Additional storage solution is available for purchase. (NOTE: The
sponge is simply for retaining the storage solution so that it doesn't spill.
It should be kept in the cap.)
How often do I need to calibrate?
All pH meters should be calibrated anywhere from before every use to at least
once a month. The frequency of calibration depends on usage and application,
but you should calibrate at least once per month for proper results and a
longer lifespan of your meter. A free packet of pH 7.0 buffer is included with
the meter. Additional pH buffers for calibration are available
for purchase. Please consult the user's guide for calibration instructions.
I use my meter for hydroponics. Does it need any
special care?
Yes. Nutrients in a hydroponics reservoir will quickly adhere to the sensor and
throw off readings. It is very important to rinse the sensor in distilled water
after each use. Otherwise, you'll just be measuring the nutrients that are
already on the sensor.
Can I use the PH-200 for testing distilled, DI or RO
water?
No. The meter is not designed for pure or very low TDS water. The water needs
at least 10 ppm of TDS (S of EC) to pick up a reading.
|