Lab Grade. High Performance. Automated. Tough.
The Milwaukee MW102 PRO+ pH meter has won fans around the
world with its reliable, fast and simple operation as well as its toughness.
Accurate to ± 0.02 pH with automatic temperature compensation. Ideal
for use by brewers, wine makers, growers and other users with challenging pH
measurement needs.
What People Are Saying
"Amazingly accurate, the best meter I have used so
far."
"Very satisfied, very accurate, rugged device that
calibrates easily."
"Rarely needs to be calibrated and gives perfect
readings every time."
"Killer tool, good value."
Summary
The Milwaukee PRO+ pH Meter is preferred by people testing
samples that cause other pH testers and meters to fail from brewers and wine
makers to hydroponic growers and farmers.
The Milwaukee PRO pH meter offers:
Accuracy
People choose the PRO+ pH Meter to improve the accuracy of
their pH testing program. With two point calibration, the meter can be quickly
calibrated to a higher accuracy compared with one point calibration. The MW102
meter is accuracy to ± 0.02 pH. 5x more accurate than some
alternative meters.
The meter comes with both a pH probe and temperature probe
allowing the meter to automatically adjust the pH reading for the effect of
temperature.
The temperature probe can also be used as a very accurate
thermometer.
Toughness
The rugged meter is built to take knocks.
Low maintenance
The PRO+ pH meter comes with the Milwaukee SE220 pH probe.
The SE220 is Milwaukee's top selling lab grade electrode for a reason. Designed
to be both low maintenance (gel filled) and able to withstand more challenging
samples (double junction). The SE220 is ideal for use in beer making,
winemaking and hydroponics.
Design features
- Fast
easy to read results with large digital LCD readout
- Extreme
accuracy to ±0.02 pH and extended range (-2.00 pH to 16.00 pH)
- Lightweight
and portable
- Easy
measurement: just place the probe in the sample, gently stir and wait for
the reading to stabilize
- Simple
push button, automatic two-point calibration for increased accuracy
- Gel-filled,
double junction lab grade pH electrode for low maintenance and high
performance with a screw on cap to ensure proper storage
- Rugged
stainless temperature probe
- 3 feet
probe cables for extra flexibility when testing
- Auto
shut off and low power demand with approx. 300 hours of continuous use
(battery included)
Care and Use
pH meters usually start performing poorly because of
problems with the probe. The two parts of the pH probe that cause problems are
the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will
eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter
to compare the sample to a reference. The reading is generated based on the
electrical difference between the sample and reference. If the junction hole
gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the
following ways.
Storage
The pH probe needs to be kept hydrated. Long periods of dry
storage will damage the sensitivity of the probe. Allowing the probe to dry out
may also result in the junction hole getting clogged.
Storing in pH probe storage solution MA9015 or pH
calibration buffers will help address both these issues. Do not store in tap
water and DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap
filled with storage solution or calibration buffer and the cap tightened to
prevent leakage. It is also recommended that to store the electrode upright to
further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the
sensing bulb and clog the junction. This is especially true if the sample has a
lot of organic material. We recommend regularly soaking your electrode in
cleaning solution MA9016.
Calibration
The pH sensing bulbs become less sensitive over time so make
sure that you are calibrating regularly to keep your PRO Plus pH meter
accurate. Also, calibrate after cleaning or a long period of storage.
Specifications
- pH
Range: -2.00 to 16.00 pH
- Temp
Range: -5 to 70°C
- pH
Accuracy ±0.02 pH
- pH
Resolution: 0.01 pH
- pH
Typical EMC Deviation: ±0.2 pH
- Temp
Resolution 0.1°C
- Temp
Accuracy (@25°C): ±0.5°C
- Temperature
Compensation: Automatic, 0 to 70°C
- Temp
Typical EMC Deviation: ±0.5°C
- Calibration:
Automatic, 1 or 2 points
- pH
Electrode: SE220 (included)
- Temperature:
Probe MA830R (included)
- Environment:
0 to 50°C / 32 to 122°F; max RH 95%
- Battery
Type: 1 x 9V (included)
- Battery
Life: Approx. 300 hours of continuous use
- Auto-off:
After 8 minutes of non-use
- Approximate
dimensions: 5.7 x 3.1 x 1.6 inches
- Weight:
1.1 lbs with battery
|